Inner ear decompression sickness in a hyperbaric chamber inside tender: a case report
Inner ear decompression sickness (IEDCS) is a rare diving complication that presents with vestibular dysfunction, cochlear dysfunction, or a combination of both. While scuba diving is a known cause, no cases have been reported in the occupational
hyperbaric setting. We present the case of a 55-year-old man who developed IEDCS after working as a hyperbaric multiplace chamber inside tender. The patient was treated with seven sessions of hyperbaric oxygen therapy, resulting in resolution of the majority of his symptoms. This case illustrates a potential occupational hazard of working in a hyperbaric chamber and demonstrates successful treatment with hyperbaric oxygen therapy.